z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG6312E

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

EDG6312E
function FAILED BECAUSE PRE-CHANGE RECORD NOT IN JOURNAL - JOURNAL RECORD NUMBER number RECORD TYPE type key

Explanation

You are running the EDGUPDT utility to apply JRNLTRAN records to the original CDS. The record set to be processed is incomplete because the expected prechange copy of the CDS record is not found in the journal.

In the message text:
function
Is the original record update recorded in the journal. It can be one of ADD, CHANGE, and DELETE.
number
The number (4 bytes in hexadecimal) of the journal record processed.
type
The type of the journal record processed. It can be one of: V for volume, or D for data set.
key
The partial key of the journal record processed.
  • For a record type V, the volser is given.
  • For a record type D, the data set name, file sequence number, and volser are listed.

System action

EDGUPDT skips the current set of journal records and continues processing. A minimum return code of 8 is set.

Operator response

N/A

Source

DFSMSrmm

Module

EDGUPDT

Storage Administrator Response

Report this error to the IBM® Support Center. Retain a copy of the file used as the JOURNAL for this EDGUPDT run. Also locate the PDA trace data created during the time when the JRNLTRAN(YES) option created these journal records.

Go to the previous page Go to the next page