CNZZ901I   MSGFLD Parameterstext

Explanation

text is:
Message   type 	REGULAR		ACTION		SPECIFIC
INTVLTIME  =     ssssssss1	ssssssss2	ssssssss3
JOBIMTIME  =     tttttttt1	tttttttt2
JOBTHRESH  =     nnnnnnnn1	nnnnnnnn2
MSGCOUNT   =     nnnnnnnn3	nnnnnnnn4	nnnnnnnn5
MSGIMTIME  =                     			 tttttttt3
MSGLIMIT   =       														    nnnnnnnn6
MSGTHRESH  =     nnnnnnnn7	nnnnnnnn8	nnnnnnnn9
NUMJOBS    =     nnnnnnn10	nnnnnnn11
SYSIMTIME  =     tttttttt4	tttttttt5	tttttttt6
[WARNING: REGULAR JOBTHRESH not < MSGTHRESH]
[WARNING: ACTION  JOBTHRESH not < MSGTHRESH]
[WARNING: SPECIFIC MSGLIMIT not < MSGTHRESH]

Message CNZZ901I is issued in response to the DISPLAY MSGFLD,PARAMETERS command and provides the current values of the Message Flood Automation parameters, based on the built-in defaults, as modified by the REGULAR, ACTION and SPECIFIC statements contained in the currently active MSGFLDxx Parmlib member.

The warning messages only appear if the REGULAR JOBTHRESH value is NOT less than the REGULAR MSGTHRESH value, the ACTION JOBTHRESH value is NOT less than the ACTION MSGTHRESH value, or the SPECIFIC MSGLIMIT value is NOT less than the SPECIFIC MSGTHRESH value.

In the message text:
ssssssss1
The REGULAR interval time in seconds.
ssssssss2
The ACTION interval time in seconds.
ssssssss3
The SPECIFIC interval time in seconds.
tttttttt1
The REGULAR job inter-message time in seconds and fractions of a second.
tttttttt2
The ACTION job inter-message time in seconds and fractions of a second.
nnnnnnnn1
The REGULAR job threshold message count.
nnnnnnnn2
The ACTION job threshold message count.
nnnnnnnn3
The REGULAR current message count.
nnnnnnnn4
The ACTION current message count.
nnnnnnnn5
The SPECIFIC current message count.
tttttttt3
The SPECIFIC message inter-message time in seconds and fractions of a second.
nnnnnnnn6
The SPECIFIC individual message message threshold count.
nnnnnnnn7
The REGULAR message threshold count.
nnnnnnnn8
The ACTION message threshold count.
nnnnnnnn9
The SPECIFIC message threshold count.
nnnnnnn10
The REGULAR maximum number of jobs to be tracked.
nnnnnnn11
The ACTION maximum number of jobs to be tracked.
tttttttt4
The REGULAR system inter-message time in seconds and fractions of a second.
tttttttt5
The ACTION system inter-message time in seconds and fractions of a second.
tttttttt6
The SPECIFIC system inter-message time in seconds and fractions of a second.

System action

Message Flood Automation processing continues.

Operator response

If any of the warning messages appear, you should correct the problem by raising the MSGTHRESH value until it is greater than the JOBTHRESH (or MSGLIMIT) value, or alternatively, by lowering the JOBTHRESH (or MSGLIMIT) value until it is less than the MSGTHRESH value. You can use the SETMF command to change these values immediately or contact your system programmer to have the values changed in the MSGFLDxx Parmlib member. If you change the values with the SETMF command, these changes will only persist until the next SET MSGFLD=xx command is issued or an IPL occurs. Changing the values in the MSGFLDxx Parmlib member will ensure that the values are properly set any time that the MSGFLDxx Parmlib member is reloaded.

System programmer response

Change the appropriate parameters and re-load the MSGFLDxx Parmlib member.

Module

CNZZDVL1

Source

Consoles (SC1CK)

Routing Code

*

Descriptor Code

5, 8, 9