CNZZ901I MSGFLD Parameterstext
Explanation
Message type REGULAR ACTION SPECIFIC
INTVLTIME = ssssssss1 ssssssss2 ssssssss3
JOBIMTIME = tttttttt1 tttttttt2
JOBTHRESH = nnnnnnnn1 nnnnnnnn2
MSGCOUNT = nnnnnnnn3 nnnnnnnn4 nnnnnnnn5
MSGIMTIME = tttttttt3
MSGLIMIT = nnnnnnnn6
MSGTHRESH = nnnnnnnn7 nnnnnnnn8 nnnnnnnn9
NUMJOBS = nnnnnnn10 nnnnnnn11
SYSIMTIME = tttttttt4 tttttttt5 tttttttt6
[WARNING: REGULAR JOBTHRESH not < MSGTHRESH]
[WARNING: ACTION JOBTHRESH not < MSGTHRESH]
[WARNING: SPECIFIC MSGLIMIT not < MSGTHRESH]
Message CNZZ901I is issued in response to the DISPLAY MSGFLD,PARAMETERS command and provides the current values of the Message Flood Automation parameters, based on the built-in defaults, as modified by the REGULAR, ACTION and SPECIFIC statements contained in the currently active MSGFLDxx Parmlib member.
The warning messages only appear if the REGULAR JOBTHRESH value is NOT less than the REGULAR MSGTHRESH value, the ACTION JOBTHRESH value is NOT less than the ACTION MSGTHRESH value, or the SPECIFIC MSGLIMIT value is NOT less than the SPECIFIC MSGTHRESH value.
- ssssssss1
- The REGULAR interval time in seconds.
- ssssssss2
- The ACTION interval time in seconds.
- ssssssss3
- The SPECIFIC interval time in seconds.
- tttttttt1
- The REGULAR job inter-message time in seconds and fractions of a second.
- tttttttt2
- The ACTION job inter-message time in seconds and fractions of a second.
- nnnnnnnn1
- The REGULAR job threshold message count.
- nnnnnnnn2
- The ACTION job threshold message count.
- nnnnnnnn3
- The REGULAR current message count.
- nnnnnnnn4
- The ACTION current message count.
- nnnnnnnn5
- The SPECIFIC current message count.
- tttttttt3
- The SPECIFIC message inter-message time in seconds and fractions of a second.
- nnnnnnnn6
- The SPECIFIC individual message message threshold count.
- nnnnnnnn7
- The REGULAR message threshold count.
- nnnnnnnn8
- The ACTION message threshold count.
- nnnnnnnn9
- The SPECIFIC message threshold count.
- nnnnnnn10
- The REGULAR maximum number of jobs to be tracked.
- nnnnnnn11
- The ACTION maximum number of jobs to be tracked.
- tttttttt4
- The REGULAR system inter-message time in seconds and fractions of a second.
- tttttttt5
- The ACTION system inter-message time in seconds and fractions of a second.
- tttttttt6
- The SPECIFIC system inter-message time in seconds and fractions of a second.
System action
Message Flood Automation processing continues.
Operator response
If any of the warning messages appear, you should correct the problem by raising the MSGTHRESH value until it is greater than the JOBTHRESH (or MSGLIMIT) value, or alternatively, by lowering the JOBTHRESH (or MSGLIMIT) value until it is less than the MSGTHRESH value. You can use the SETMF command to change these values immediately or contact your system programmer to have the values changed in the MSGFLDxx Parmlib member. If you change the values with the SETMF command, these changes will only persist until the next SET MSGFLD=xx command is issued or an IPL occurs. Changing the values in the MSGFLDxx Parmlib member will ensure that the values are properly set any time that the MSGFLDxx Parmlib member is reloaded.
System programmer response
Change the appropriate parameters and re-load the MSGFLDxx Parmlib member.
Module
CNZZDVL1
Source
Consoles (SC1CK)
Routing Code
*
Descriptor Code
5, 8, 9