CNZHF0006E One or more EMCS consoles are defined with a multi-system message scope and are receiving the hardcopy message set.
Explanation
EMCS consoles with multi-system message scopes that receive the hardcopy message set process a large number of messages. This can affect message processing times and console availability.
System action
The system continues processing.
Operator response
Report this problem to the system programmer.
System programmer response
To view the attributes of all EMCS
consoles configured to receive the hardcopy message set, issue the
following command:
DISPLAY EMCS,FULL,STATUS=L,ATTR=HC
To
change the message scope of an EMCS console, issue the VARY CN system
command with either the MSCOPE or DMSCOPE parameter. Note
that the VARY CN system command can only be used to set the attributes
of an active console. If an EMCS console is not active, find
out which product activated it and contact the product owner. If
the EMCS console is no longer needed, use the EMCS console removal
service (IEARELEC) to remove the EMCS console definition.You can now use the SETCON DELETE system command or the EMCS console removal service (IEARELEC in SYS1.SAMPLIB) to remove any EMCS console definition that is no longer needed.
Problem determination
N/A
Module
CNZH1CKF
Source
Consoles (SC1CK)
Reference Documentation
Automation
N/A
Routing Code
-
Descriptor Code
3