CNZHF0006E   One or more EMCS consoles are defined with a multi-system message scope and are receiving the hardcopy message set.

Explanation

EMCS consoles with multi-system message scopes that receive the hardcopy message set process a large number of messages. This can affect message processing times and console availability.

System action

The system continues processing.

Operator response

Report this problem to the system programmer.

System programmer response

To view the attributes of all EMCS consoles configured to receive the hardcopy message set, issue the following command:
DISPLAY EMCS,FULL,STATUS=L,ATTR=HC
To change the message scope of an EMCS console, issue the VARY CN system command with either the MSCOPE or DMSCOPE parameter. Note that the VARY CN system command can only be used to set the attributes of an active console. If an EMCS console is not active, find out which product activated it and contact the product owner. If the EMCS console is no longer needed, use the EMCS console removal service (IEARELEC) to remove the EMCS console definition.

Start of changeYou can now use the SETCON DELETE system command or the EMCS console removal service (IEARELEC in SYS1.SAMPLIB) to remove any EMCS console definition that is no longer needed.End of change

Problem determination

N/A

Module

CNZH1CKF

Source

Consoles (SC1CK)

Automation

N/A

Routing Code

-

Descriptor Code

3