CNZ4301I   CONSOLE console-name WAS NOT REMOVED. text

Explanation

The console definition for the console named in the message could not be removed.

In the message text:
console-name
The name of the console whose definition was not removed.
CONSOLE IS ACTIVE
An active console cannot be removed. Deactivate the console prior to removing it.
CONSOLE IS NOT DEFINED
The console named in the message is not defined.
CONSOLE IS NOT Start of changeANEnd of change MCS/SMCSStart of change/HMCSEnd of change/SUBSYSTEM CONSOLE
Only console definitions for MCS/SMCS/Start of changeHMCS/End of changeSUBSYSTEM consoles can be removed.
FAILURE OCCURRED DURING PROCESSING
An error occurred before the console named in the message could be removed. An ABEND will be issued to generate an SVC dump. In most cases, message CNZ0001I will be issued to provide further diagnostics.
CALLER IS NOT IN SUPERVISOR STATE
Only callers running in supervisor state can remove console definitions.
CALLER IS NOT IN KEY ZERO
Only callers running in key zero can remove console definitions.
CALLER IS IN CROSS MEMORY MODE
Only callers not running in cross memory mode can remove console definitions.
CALLER IS HOLDING LOCKS
Only callers not holding locks can remove console definitions.
CALLER IS NOT IN TASK MODE
Only callers running in task mode can remove console definitions.

System action

The system does not remove the console definition for the console named in the message.

Operator response

Notify the system programmer.

System programmer response

See the explanation in the corresponding insert.

Module

IEAVG730, CNZM1MRB

Source

Consoles (SC1CK)

Routing Code

Start of changeHardcopy only or sent to the issuer of the SETCON command.End of change

Descriptor Code

5