CBR2180I Abend xxxx occurred in the mmmmmmmm exit module. Dynamic exit name = eeeeeeee, Abend reason code = ssss.
Explanation
The object tape volume return to MVS™ scratch installation exit module, received control and abnormally terminated. The dynamic exit name is eeeeeeee, exit module name is mmmmmmmm, abend code is xxxx, and abend reason code is ssss.
System action
OAM continues releasing object tape volumes to MVS scratch. The object tape volume return to MVS scratch installation exit module is deactivated, and will not be invoked again until reactivated.
Operator response
Inform your system programmer.
System programmer response
Use CBR2165I messages to synchronize for any object tape volumes released by OAM while the exit is deactivated. Perform the following steps:
- Determine the cause of the failure by analyzing the system dump using IPCS.
- Correct the source code in the exit module.
- Recompile or assemble the exit module.
- Link a new version of the exit module into the program library containing the exit module.
- If the program library containing the exit load module, is managed by the Library Lookaside Facility (LLA), then use the MVS operator MODIFY LLA command, in conjunction with a CSVLLAxx PARMLIB member, to refresh the load module being managed by the Library Lookaside Facility.
- Reactivate the exit module, issue SETPROG EXIT commands at an MVS system console.
Programmer response
None.
Module
CBRSXTVS
Source
Object Access Method (OAM)
Routing Code
2,3
Descriptor Code
4