CBR0343I   A START RECYCLE command is currently active. Operand cannot be set to 0 while there is an active START RECYCLE command.

Explanation

OAM is processing a MODIFY OAM, UPDATE, SETOAM operator command to update operand with a value of 0 while a MODIFY OAM, START, RECYCLE command is active. A value of 0 is not valid for operand while there is an active MODIFY OAM, START, RECYCLE command processing.

Valid values for operand are MAXRECYC and SGMAXREC.

System action

The MODIFY OAM, UPDATE, SETOAM operator command is failed. The existing value for operand remains in effect.

Operator response

If a value of 0 is desired for operand, then either an F OAM, STOP, RECYCLE command must be issued to terminate the active START RECYCLE command, or wait until the active START RECYCLE command processing completes normally. Then issue the MODIFY OAM, UPDATE, SETOAM command specifying operand with a value of 0 while there is not an active START RECYCLE command. This will cause a subsequent F OAM, START,RECYCLE command to be processed with an operand value of 0.

System programmer response

None.

Source

Object Access Method (OAM)

Routing Code

2

Descriptor Code

4