CBR0217I   Invalid volume attribute flags value attribute-flags-value associated with tape volume volser.

Explanation

During OAM initialization and configuration validation, OAM discovered that the volume attribute flags column (VOLATTRF) in the row in the tape volume table (TAPEVOL) in the optical configuration database for volume volser contains an invalid volume attribute flags value.

In the message text:
attribute-flags-value
The invalid volume attribute flags value in hexadecimal. Only the following flags are valid:
  • X'02' - The volume is enabled for block sizes greater than 32760
  • X'01' - The volume is logical WORM.
Therefore any value other than 0, 1, 2, or 3 is not valid.

System action

OAM initialization continues. The tape volume row is skipped. Until the table row is changed to contain a valid value, and OAM is stopped then started to recognize the new valid value, no work that requires the skipped volume will be done. The requests will fail with a return and reason code pair that indicates that OAM does not know about the volume that is skipped during initialization.

Operator response

Notify the system programmer.

System programmer response

Using SPUFI (SQL Processing Using File Input) under DB2I (DB2® Interactive), correct the volume attribute flags value (VOLATTRF) in the row in the tape volume table in the optical configuration database. When the row contains a valid value, stop and start OAM, so that OAM will recognize the changed volume attribute flags column. Recognition of the valid volume attributes flag value will add the volume to OAM's inventory so that requests for the volume can be processed again.

Source

Object Access Method (OAM)

Routing Code

2

Descriptor Code

4