CBR5887I Power-up diagnostics aborted on drive drive-name.
Explanation
An I/O error has occurred on optical disk drive drive-name. The optical disk drive returned a fault code of X'A5' This fault code is reported in conjunction with a UNIT ATTENTION when the power-up diagnostics were not completed because the LaserDrive 1200 responded to a Selection. In order for the LaserDrive 1200 to complete the self-test diagnostics, no host should select the LaserDrive 1200 for the first 3 minutes after power-up.
System action
The I/O operation is stopped.
Operator response
Notify the service representative.
System programmer response
For information on optical drive fault codes, consult LASERDRIVE** 1200 Engineering Specification. Obtain the logrec data set error record.
Source
Object Access Method (OAM)
Routing Code
4
Descriptor Code
4