CBR4461I {RELABEL | REFORMAT} volume old_volser failed. {Mount error | DB2 error | Internal service error | Label I/O error | Volume write protected | Check previous messages | VOLSER not unique | DB2 Object Directory table error}.
Explanation
An attempt to relabel or reformat a 3995 optical
disk volume old_volser has failed. The reason for
the failure is one of the following:
- Mount error
- An attempt to mount the volume to be labeled failed. A drive error message precedes this message and provides a detailed description of the error.
- DB2® error
- An attempt to delete, update, or insert the rows of DB2 Volume Table failed. Refer to the previous error message for details of this error.
- Internal service error
- The attempt to serialize the new volume serial number failed. Refer to the previous error message for details of this error.
- Label I/O error
- An error occurred during a volume label operation for the mounted side of the cartridge. A drive error message precedes this message and provides a detailed description of the error.
- Volume write protected
- The 3995 controller indicates that the volume is currently set to write protected.
- Check previous messages
- An error occurred during a volume format operation for the mounted side of the cartridge. A drive error message precedes this message and provides a detailed description of the error.
- VOLSER not unique
- The new volume serial number already exists in the optical configuration database. Refer to the error message that preceded this one for details of this current error.
- DB2 Object Directory table error
- An error occurred when accessing the DB2 Object Directory. Refer to the error message that preceded this one for details of this current error.
System action
If the cartridge was successfully mounted on the selected operator accessible drive, OAM attempts to spin down and eject the cartridge.
Operator response
Follow the instructions in the previous error message.
Source
Object Access Method (OAM)
Routing Code
2, 4, 6
Descriptor Code
4