CBR4437I   Label processing on drive drive-name failed. {Demount error | Mount error | Eject error | Flip error | Format error | Volume already known | Operator cancel | STORAGE OBTAIN failure | DB2 insert failure | WORM scratch volume full}.

Explanation

An attempt to label both volumes on a 3995 optical disk cartridge using operator-accessible drive drive-name has failed. The reason for the failure is one of the following:
Demount error
An optical disk cartridge was already mounted in the drive on which label processing was to be performed. The attempt to demount the cartridge ended in error. A drive error message precedes this message and provides a detailed description of the error.
Mount error
The attempt to mount the cartridge to be labeled failed. A drive error message precedes this message and provides a detailed description of the error.
Eject error
The attempt to spin down and eject the cartridge currently mounted in the drive failed. A drive error message precedes this message and provides a detailed description of the error.
Flip error
An attempt to flip the mounted cartridge failed. A flip is requested when one side of the cartridge has been successfully formatted, and the other side is to be processed. A drive error message precedes this message and provides a detailed description of the error.
Format error
An error occurred during a volume format operation for the mounted side of the cartridge. A drive error message precedes this message and provides a detailed description of the error.
Volume already known
One of the volumes on the cartridge has already been formatted, and the volume serial number already exists in the optical configuration database. Details of this error are in message CBR4418I, which has already been issued.
Operator cancel
The operator used the response to message CBR4422D to cancel the label processing request.
STORAGE OBTAIN failure
The attempt to acquire storage for a volume control block failed. Details of this error are in message CBR7004I, which has already been issued.
DB2® insert failure
The attempt to insert two rows into the volume table in the optical configuration database failed. Details of this error are in message CBR7585I, which has already been issued.
WORM scratch volume full
The amount of free space on the WORM volume that was labeled and assigned to scratch was less than the number of kilobytes that are specified on the SCRENTRYTHRESHOLD parameter in the CBROAMxx member of PARMLIB. Message CBR4452D was issued to verify that the label should continue, and the operator reply indicated that the label operation should fail.

System action

If the cartridge was successfully mounted into the selected drive, OAM attempts to spin down and eject the cartridge.

Operator response

For WORM scratch volume full, enter different cartridge into the library. For all other errors, follow the instructions in the previous error message.

Source

Object Access Method (OAM)

Routing Code

2, 4, 6

Descriptor Code

4