CBR4436I   Volumes volser-1 and volser-2 entered into library library-name. volser-3 is part of OAM configuration. volser-4 is not.

Explanation

Volumes volser-1 and volser-2 have been entered into library library-name as opposite sides of the same optical disk cartridge. One of the volumes - given by volser-3 - already exists in the optical configuration database, but the other - given by volser-4 - does not. If one of the volumes is unformatted, then '??????' is substituted for volser4.

System action

OAM stops cartridge entry processing, ejects the entered cartridge, and issues message CBR4434I.

Operator response

Use DISPLAY SMS,VOLUME to display information about the optical volumes. Inform the system programmer.

System programmer response

If the optical configuration database is wrong, stop the OAM address space, then use DB2® SPUFI to make corrections. When the database has been corrected, restart OAM and reenter the cartridge.

Source

Object Access Method (OAM)

Routing Code

2, 4, 6

Descriptor Code

4