CBR4099I Library library-name permanent I/O error. Sense not available.
Explanation
An error has been detected during Library Automation
Communication Services (LACS) processing for the MOUNT or DEMOUNT
function. Library library-name returned a permanent
I/O error indication in response to the mount or demount order. Library
sense information is not available. One of the following situations
exists:
- The error was not a unit check.
- The error was a unit check, but the sense information could not be read.
- The error was a unit check, the sense information could be read, but the sense record did not describe a library related error.
System action
The LACS request fails with a permanent error return code. Messages issued by the caller of LACS are written concurrently with this message.
Operator response
Search problem reporting databases for a fix for the problem. If no fix exists, contact an IBM® service representative to repair the library.
Programmer response
Resubmit the failing job.
Source
Object Access Method (OAM)
Routing Code
Set by the caller.
Descriptor Code
Set by the caller.