CBR3966I   Remap of library library-name-1 found wrong library library-name-2 for volume volser. Eject scheduled.

Explanation

During remap verification of the controller map (outboard inventory), volume volser was found in library library-name-1 but the volume table indicates the volume is in library library-name-2. This message is issued to the TSO/E userid of the ISMF storage administrator who originated the remap request for this library and to the operator console.

System action

Cartridge is scheduled for eject.

System programmer response

Audit volume volser to verify if it actually resides in library library-name-2. If it does, the volume being ejected from library library-name-1 is a duplicate volume. If the audit of volume volser does not find the volume in library library-name-2, request a remap of library library-name-2 in order to locate the missing volume.

Source

Object Access Method (OAM)

Routing Code

2,4,6

Descriptor Code

4