CBR3899I Protocol error of psc received from device controller trying to access library library-name.
Explanation
The device controller has determined that the
communications packet, CBRPAC, is in error. The specific error may
be referenced below by using the protocol status code (psc) value:
1 - packet ID is incorrect
2 - length of packet out of range
3 - command type not recognized
4 - SCSI bus ID out of range
5 - logical unit number out of range
6 - length of data out of range
7 - library number out of range
8 - protocol error status
9 - checksum error
System action
Depending upon the operation that was issued to library library-name, OAM may continue.
Operator response
Notify the system programmer.
System programmer response
Use the psc, above, to determine the reason for the error. If the problem recurs and if the program is not in error, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Obtain the logrec data set error record.
Source
Object Access Method (OAM)
Routing Code
4
Descriptor Code
4