CBR3757E   Library library-name in {paused | manual mode} operational state.

Explanation

Library library-name is no longer running in the automated (normal) operational state. The operational state is one of the following:
paused
All mechanical motion within the library has stopped. Paused operational state is entered automatically when a failure within the library prevents further automated operation, or explicitly by command from the library manager operator console. The library manager continues to accept orders from the host but queues them for execution after the paused operational state has changed to automated or manual mode operational state.
manual mode
All mechanical motion within the library has stopped. Manual mode operational state is entered explicitly by command from the library manager operator console. The library manager continues to accept orders from the host, then provides explicit instructions to the operator to perform manually the functions which would normally be done automatically, such as volume fetch and mounting.

System action

Usage of the library continues in nearly normal fashion. There may be an impact on performance, since library operations are either queued for later execution or executed manually. This message is retained until the library has returned to the automated operational state.

Operator response

Determine why the library is no longer in automated operational state. If repair action is required, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

Object Access Method (OAM)

Routing Code

2,3,5

Descriptor Code

11