CBR3688I Unable to perform export completion processing for logical volume volser from library library-name1. Possible duplicate volume in library library-name2.
Explanation
Even though logical volume volser has been successfully exported to a stacked volume in library library-name1, the host was unable to complete the export process. The host detected that a possible duplicate volume resides in library library-name2.
System action
The logical volume remains in the library in the exported category to be processed by another host.
System programmer response
If the volume remains in the exported category after having been processed by all hosts, determine why the volume record in the TCDB does not indicate that the volume resides in the library in which the volume was exported. Once the problem has been resolved, the library name in the volume record can be corrected by using IDCAMS. Once the volume record has been corrected, the LIBRARY RESET, CBRUXEJC command can be used to reprocess the volumes left in the exported category.
Source
Object Access Method (OAM)
Routing Code
2,3,5
Descriptor Code
4