CBR3646D Entry of CBRUXVNL volume volser into library library-name still pending. Reply 'R' to retry or 'C' to cancel.
Explanation
The volume not in library installation exit (CBRUXVNL)
has returned control indicating that the operator has placed volume volser into
library library-name, however from a host perspective,
the volume has not yet completed cartridge entry processing. At the
point in time in which this message has been issued, we will have
repeatedly checked (in 30 second time intervals for approximately
15 minutes), for the completion of entry processing by the creation
or update of the tape configuration data base (TCDB) volume record
indicating that the volume is now library resident. If the library
name specified is ????????, any library could have satisfied
the request; otherwise, the volume should have been entered into the
specified target library. This message may have occurred for any one
of the following reasons:
- Locating and entering the volume took longer than expected.
- The volume was incorrectly entered into the wrong library.
- The volume is still in the library manager insert category and has not yet been processed by the host.
- The volume went through, but failed entry processing in which case the volume may still be in the insert category or it may have been ejected.
System action
If the operator replies 'R', repeated attempts are again made to check for entry of the volume. If the volume is successfully entered, job processing continues. If volume is not successfully entered within the allotted time period, this message is again issued.
If the operator replies 'C', the job is canceled.
Operator response
If the entry problem cannot be corrected, reply 'C'; otherwise, when the problem has been corrected, reply 'R' to continue the retry attempt.
Source
Object Access Method (OAM)
Routing Code
2,3,5
Descriptor Code
2