CBR3646D   Entry of CBRUXVNL volume volser into library library-name still pending. Reply 'R' to retry or 'C' to cancel.

Explanation

The volume not in library installation exit (CBRUXVNL) has returned control indicating that the operator has placed volume volser into library library-name, however from a host perspective, the volume has not yet completed cartridge entry processing. At the point in time in which this message has been issued, we will have repeatedly checked (in 30 second time intervals for approximately 15 minutes), for the completion of entry processing by the creation or update of the tape configuration data base (TCDB) volume record indicating that the volume is now library resident. If the library name specified is ????????, any library could have satisfied the request; otherwise, the volume should have been entered into the specified target library. This message may have occurred for any one of the following reasons:
  • Locating and entering the volume took longer than expected.
  • The volume was incorrectly entered into the wrong library.
  • The volume is still in the library manager insert category and has not yet been processed by the host.
  • The volume went through, but failed entry processing in which case the volume may still be in the insert category or it may have been ejected.

System action

If the operator replies 'R', repeated attempts are again made to check for entry of the volume. If the volume is successfully entered, job processing continues. If volume is not successfully entered within the allotted time period, this message is again issued.

If the operator replies 'C', the job is canceled.

Operator response

If the entry problem cannot be corrected, reply 'C'; otherwise, when the problem has been corrected, reply 'R' to continue the retry attempt.

Source

Object Access Method (OAM)

Routing Code

2,3,5

Descriptor Code

2