CBR3354I   Library library-name was unable to complete an interrupted move at power-up.

Explanation

If a move was interrupted by a power loss, the library will attempt to return to the state before the last command was issued. Library library-name was unable to restore itself to the previous state before the last command was issued. It is likely that a cartridge has been removed.

System action

The I/O operation is stopped.

Operator response

Notify the system programmer. Contact hardware support.

System programmer response

The 3995 library and OAM configuration table are corrupted. A remap is recommended to correct the discrepancy. If the sense data displayed in the previous CBR3300I message does not equal zero then obtain the SYS1.LOGREC error record.

Source

Object Access Method (OAM)

Routing Code

2,4,6

Descriptor Code

4