CBR3310I   Error with no additional sense in library library-name.

Explanation

No sense information describing an error is pertinent. A Request Sense command was sent when no error was outstanding or an error was detected with no associated sense information. If the error was detected when a move command was being implemented, the location of the cartridge being moved may not be known. The cartridge may be lost. If this is the case, the cartridge will be found missing on the next request for that cartridge.

System action

The I/O operation is stopped.

Operator response

Contact hardware support.

System programmer response

If the sense data displayed in the previous CBR3300I message does not equal zero then obtain the SYS1.LOGREC error record.

Source

Object Access Method (OAM)

Routing Code

2,4,6

Descriptor Code

4