CBR3306I   The I/O station in library library-name is no longer usable.

Explanation

An I/O error has occurred in library library-name that rendered the I/O station unusable.

System action

The I/O station is marked not operational, causing all subsequent enter and eject requests to fail until the library is varied offline and then back online.

Operator response

Vary the library offline and then back online. If the I/O station continues to fail, contact hardware support.

System programmer response

Check the system log for previous messages that may have been issued giving details on the exact failure. If the previous message CBR3300I was issued for this failure and the sense data displayed is not all zeros, then obtain the SYS1.LOGREC error record.

Source

Object Access Method (OAM)

Routing Code

2,4,6

Descriptor Code

4