CBR3213I Gripper 1 limit sensor fault in library library-name.
Explanation
An I/O error has occurred implementing a library command. Library library-name returned a fault 141 indicating that during implementation of a Home command both gripper 1 limit sensors were on at once.
System action
The I/O operation is stopped.
Operator response
Contact hardware support.
System programmer response
For information on library errors, consult Filenet OSAR Library Unit Product Description. Obtain the logrec data set error record.
Source
Object Access Method (OAM)
Routing Code
4
Descriptor Code
4