CBR3126I   Unable to schedule {mount | demount | flip | enter | eject | start | stop | audit | remap | export completion} request to library library-name, {I/O station not operational | ESTAE failure | STORAGE OBTAIN failure}.

Explanation

A mount, demount, flip, enter, eject, start, stop, audit, remap or export completion request has been made to library library-name. The request failed for one of the following reasons:
  • The I/O station is not operational.
  • An ESTAE request failed.
  • A STORAGE OBTAIN request failed.

System action

For an ESTAE or STORAGE OBTAIN failure, message CBR7010I or message CBR7004I was already issued.

Operator response

If the I/O station is not operational, contact hardware support. Otherwise, contact the systems programmer.

System programmer response

For an ESTAE failure see message CBR7010I, and for a STORAGE OBTAIN failure see message CBR7004I.

Source

Object Access Method (OAM)

Routing Code

2,4,6

Descriptor Code

4