CBR1063I Command rejected. Volume serial number volser invalid.
Explanation
The operator has entered a command that requires
the specification of a volume serial number:
DISPLAY SMS,VOL(volser)
MODIFY OAM,EJECT,volser
LIBRARY EJECT,volser
MODIFY OAM,START,RECOVERY,volser
MODIFY OAM,UPDATE,VOLUME,volser....
The volume serial number volser does not conform to MVS™ volume serial number naming conventions or the volume serial number naming conventions appropriate for tape libraries.
System action
The command is rejected.
Operator response
Determine the cause of the error; then enter a command with a valid volume serial number.
Source
Object Access Method (OAM)
Routing Code
2
Descriptor Code
5