CBR0182I   Unknown storage group name storage-group-name specified for volume volser.

Explanation

One of the following statements is true for storage group storage-group-name specified for volume volser:
  • The storage group is not defined in the SMS ACDS.
  • The storage group definition in the SMS ACDS contained errors.
  • The storage group is defined in the SMS ACDS, however it is enabled to more than one system in a sysplex, and this instance of OAM does not belong to an OAMplex; therefore, any object storage groups enabled to more than one system are ignored.

System action

The volume is added to the optical configuration. OAM initialization continues.

Operator response

Notify the system programmer.

System programmer response

If the storage group name in the volume definition is in error, correct the storage group name in the Volume Table in the DB2® optical configuration database, using SPUFI. If the storage group definition is missing from the SMS CDS, add the definition using the ISMF Storage Administrator object storage group or object backup storage group define panel. If the storage group definition is in error, follow the instructions for the message describing that error. If a new configuration is being activated, and either the volume is not to be part of that configuration, or the volume will always be used by specifying the volume serial number, no action is necessary. One may want choose this volume above others, however, if the library is full and it is necessary to perform a volume eject.

Source

Object Access Method (OAM)

Routing Code

2

Descriptor Code

4