CBR0147I   No optical drive definition was found in the active SMS configuration during OAM initialization.

Explanation

An optical library was defined in the active SMS configuration, but there are no corresponding optical disk drives defined in the active SMS configuration.

System action

OAM initialization stops. No useful work can be done until a new SMS configuration has been activated.

Operator response

Notify the system programmer.

System programmer response

Define the correct complete SMS configuration using the ISMF Storage Administrator library, drive, and storage group define panels. When the definitions are completed, activate the modified SMS control data set (CDS), then start OAM with the new active SMS configuration.

Source

Object Access Method (OAM)

Routing Code

2

Descriptor Code

4