CBR0023I Storage unavailable for CTC work area. Initialization terminated.
Explanation
An error occurred during the CTC initialization phase of OAM initialization. For each channel-to-channel adapter device used by OAM, a CTC work area is obtained from subpool 241 using the STORAGE OBTAIN macro and anchored to the MVS™ unit control block. The STORAGE OBTAIN macro for one of the CTC work areas failed. This message is preceded by message CBR7004I, which indicates the failing return code from the STORAGE macro.
System action
OAM initialization stops.
Operator response
Notify the system programmer.
Programmer response
Determine the cause of the STORAGE error by investigating the return code from the STORAGE macro and referring to the documentation for message CBR7004I.
Source
Object Access Method (OAM)
Routing Code
2
Descriptor Code
4