CBR3626I Entry of volume volser into library library-name failed. Unable to obtain the attributes for the volume.
Explanation
Volume volser could not be entered into library library-name. The attributes for the volume, which include the outboard policy names, could not be obtained from the library. See the secondary error message for a description of the failure.
System action
The volume remains in the library in the insert category and is processed as part of the next enter request. Cartridge entry processing in this library is suspended until more volumes have been entered into the library or until OAM is stopped and restarted. The LIBRARY RESET command may be used to resume cartridge entry processing.
System programmer response
Refer to the secondary error message.
Source
Object Access Method (OAM)
Routing Code
2,3,5
Descriptor Code
4