CRU012I SMF INSERT WAS SUPERSEDED AND WAS THE OLDEST RECORD FOR ( t ) catalog
entryname /nn NEWER: smftype FROM
SYS sysid AT
hh:mm:ss.hh ON mm/dd/yy
(yy.ddd)OLDER: NONE RECORD IS
BYPASSED, ACTION
WAS TAKEN
FOR A MORE CURRENT RECORD
Explanation
The record is for an entry of type t named catalog entryname, extension number nn. For t, A=nonVSAM, B=GDG, C=cluster, E=VSAM extension, G=AIX, J=GDG extension, R=path, T=truename, U=catalog connector, X=alias. nn=00, except for types E and J.
The oldest record for this catalog entry is an INSERT resulting from an smftype (DEFINE or ALTER) by the system with identifier sysid at the time and on the date indicated on the NEWER message line. The catalog entry did not appear in the EXPORTed copy.
This message should appear only in a chain of messages following CRU113I, CRU205I, CRU206I, CRU207I or CRU208I.
System action
After taking the action indicated in the last message line, processing continues.
Operator response
Use this additional information for responding to the preceding CRU113I, CRU205I, CRU206I, CRU207I or CRU208I message.