z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


BPXF001I

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

BPXF001I
A FILE SYSTEM WITH FILESYSTYPE type FAILED TO INITIALIZE. THE SOFTWARE LEVEL IS INCORRECT.

Explanation

During z/OS UNIX initialization, one of the physical file systems could not be initialized.

In the message text:
type
The value specified with the TYPE parameter of the FILESYSTYPE statement in the BPXPRMxx parmlib member.

System action

How the file system type is handled depends on the restart option chosen by the file system.
  • If the option is to be prompted for restart (which is the default option), the error that caused the problem can be corrected, and then the prompt responded to.
  • If the option is to not start this file system type, the system will continue to run without that file system type.

Operator response

Contact the system programmer.

System programmer response

If any of the following are displayed as the FILESYSTYPE, report this to your IBM® Support Center: BPXFCSIN, BPXFPINT, BPXFTCLN, BPXFTSYN.

Try to determine the cause of the failure. Check the level of the software and verify that it is compatible with the level of z/OS UNIX.

Module

BPXFSLM

Source

z/OS UNIX System Services kernel (BPX)

Routing Code

2

Descriptor Code

4

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014