Explanation
RRS detected an attempt to cold start RRS while
RRS was active. The condition that caused RRS to detect the cold start
request is indicated by reason.
In the message
text:
- reason
- is one of the following:
- LOGSTREAM VERSION MISMATCH.
- RRS detected a different version of the RM.DATA log stream from
the one to which RRS was previously connected.
- LOGSTREAM EMPTY.
- RRS detected an empty RM.DATA log stream after a cold start.
System action
The RRS address space ends.
Operator response
Inform your system programmer.
System programmer response
Depending on the
reason,
determine why the problem occurred:
- LOGSTREAM VERSION MISMATCH
- Determine whether deleting and redefining the RM.DATA log stream
definition in the LOGR policy was intentional. If so, to avoid this
message in the future, cancel all active RRS members in the RRS group
before redefining the RM data log stream.
If it was not intentional,
rework your procedures for redefining the RRS RM.DATA log stream to
avoid the problem in the future.
- LOGSTREAM EMPTY
- Determine if an application other than RRS could have deleted
log data from the RM.DATA log stream. If so, either change the application
or remove its authorization to update the log stream. Only RRS should
have update authority to the RM.DATA log stream.
If there were
no applications in the installation that could have deleted log data
from the RM.DATA log stream, search problem reporting databases for
a fix for the problem. If no fix exists, contact the IBM® Support Center.
Module
Source
Resource recovery services (RRS)