z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ATB112I

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

ATB112I
DISPLAY APPC UNAVAILABLE. APPC IS TERMINATING AND WILL AUTOMATICALLY RESTART.

Explanation

Because an internal error occurred in Advanced Program-to-Program Communication (APPC), APPC is ending and will automatically begin re-initialization. The system cannot display the output requested by a DISPLAY APPC command.

System action

The system continues initializing APPC. The system issues message ATB007I when APPC is initialized.

Operator response

Wait until the system issues message ATB007I. Then enter the DISPLAY APPC command again.

Module

ATBCODP

Source

APPC/MVS

Routing Code

2

Descriptor Code

5

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014