ATB015I APPC IS STARTING AFTER A FAILED RESTART. SPECIFIED PARMLIB
MEMBER(S) ARE IGNORED. ExplanationAdvanced Program-to-Program Communication (APPC) is starting after an attempt to internally restart failed. Message ATB005I was issued prior to the issuance of this message to record that internal restart processing was being initiated. APPC will restart with the same environment that existed prior to the internal restart attempt. Any specified APPC parmlib members will be ignored. If the installation desires to change the APPC configuration to something other than what existed prior to the failed internal restart, APPC must be canceled and started again. System actionAPPC initialization processing continues to restore the logical unit configuration that existed prior to the failed internal restart. The system issues message ATB007I when APPC becomes active again. System programmer responseIdentify the problem that prevented APPC from internally restarting successfully. The reason for the failure may have been recorded by a symptom record written to the logrec data set or a message issued to the system log data set. Keep the symptom record or system log information for future reference as it may be needed for problem determination. ModuleATBINIT SourceAPPC/MVS Routing Code2 Descriptor Code4 |