ASB060I
ASCH FAILED TO START CLASS classname INITIATORS.

Explanation

The APPC/MVS transaction scheduler failed to start initiators for the class classname. Possible causes of this error are:
  • The ASCHINT procedure is missing from SYS1.PROCLIB
  • The ASCHINT procedure contains JCL errors.

System action

The system continues processing. No initiators are started until the problem is corrected.

Operator response

Notify the system programmer. At the request of the system programmer, issue the SET ASCH=xx command to resume attempts to start initiators. If necessary, see z/OS MVS System Commands for the SET ASCH command syntax.

System programmer response

Make sure that the ASCHINT procedure is in SYS1.PROCLIB. If it is, check for any JCL errors and correct them. Then, ask the operator to restart initiators through a SET ASCH=xx operator command, specifying an ASCHPMxx parmlib member that contains one CLASSADD statement for each class that needs to be restarted.