z/OS MVS System Messages, Vol 3 (ASB-BPX)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ATR122E

z/OS MVS System Messages, Vol 3 (ASB-BPX)
SA38-0670-00

ATR122E
WRITES TO LOGSTREAM logstreamname DELAYED DUE TO OFFLOAD FAILURE

Explanation

While attempting to write data to the specified logstream, system logger rejected the request, because the coupling facility is full and offload has failed.

In the message text:
logstreamname
The name of the logstream in error.

System action

The system retries the write periodically until the write is successful. Once the write is successful, this message is deleted by the system.

Operator response

Notify the system programmer.

System programmer response

Determine why offload cannot occur for the specified logstream and fix the error.

Module

ATRBMTME

Source

Resource recovery services (RRS)

Routing Code

1,2

Descriptor Code

12

Go to the previous page Go to the next page