Explanation
The VTOC was in a flash copy relationship when
the Flash Copy relationship was withdrawn. To avoid an inaccessible
VTOC, a reinitialization of the volume was automatically attempted.
- rc
- Meaning
- 0
- The volume was successfully reinitialized.
- 12
- The volume reinitialization failed. The VTOC of the copy pool
backup storage group volume, volser, might no longer
be usable.
- reason code for rc 12
- Meaning
- 4
- SYS data set allocation failed.
- 8
- SYSDS OPEN failed.
- 10
- Volume allocation failed.
- 12
- ICKDSF failed.
- 14
- Could not obtain UCB.
System action
DFSMShsm processing continues.
Programmer response
- rc
- Response
- 0
- If the volume is shared across a sysplex, the volume needs to
be varied offline and online again on the other shared systems to
recognize the new VTOC.
- 12
- The VTOC of the copy pool backup storage group volume, volser,
might be corrupt necessitating a reinitialization. See Device Support Facilities (ICKDSF) User's Guide and Reference for
initialization procedures. If the volume cannot be reinitialized through
ICKDSF, search problem reporting databases for a fix for the problem.
If no fix exists, contact the IBM® Support
Center.