ARC1674I
LONG RUNNING COMMAND FAILED - FUNCTION IS HELD AND REQUEST SPECIFIED WAIT

Explanation

A DFSMShsm long-running command was failed before it could be started. The corresponding function is held, and the initial request specified the WAIT option. The function being held can be determined from the reason code in the preceding ARC1001I message.

The values for the reason-code are:
4
The audit function is held.
8
The list function is held.
12
The report function is held.
16
The recycle function is held.
20
The tape copy function is held.
24
The tape replace function is held.
28
The expire backup versions function is held.

System action

DFSMShsm did not start the function. DFSMShsm processing continues.

Programmer response

If the command must be run immediately, you should issue the RELEASE command with the appropriate parameter to release the desired function. Then the command can be reissued. Otherwise, the command should be reissued when the function is released later on.

Source