ARC1159I
RECOVERY FAILED - ERROR DELETING OR ALLOCATING EXISTING DATA SET

Explanation

Recovery of a VSAM data set has been in progress when either a deletion of the existing data set fails for a reason other than its catalog entry has not been found, or an allocation error has occurred. Message ARC1001I gives the base cluster name being recovered. For a deletion error, the reason code is the VSAM catalog return code, as documented by Message IDC3009I in z/OS MVS System Messages, Vol 6 (GOS-IEA). For an allocation error, the preceding message ARC0503E gives the base cluster name being allocated. Message ARC0503E also gives the return code, reason code, and information code from dynamic allocation. The reason code in preceding message ARC1001I is the return code from dynamic allocation.

System action

Recovery of the VSAM data set ends. DFSMShsm processing continues.

Programmer response

For a deletion error, make the corrections indicated by the VSAM catalog return code as documented by message IDC3009I in z/OS MVS System Messages, Vol 6 (GOS-IEA). For an allocation error, take corrective action based on the meaning of the return code and reason code issued in the message ARC0503E.

Source

DFSMShsm