DFSMShsm was attempting to write a record to one of its control data sets and received a control-interval-busy status from VSAM. DFSMShsm attempted to write the record every second for 30 seconds and got the same result.
This message can also occur if DFSMShsm was requested to shut down while the retries were occurring. In this case, there might not be an error.
DFSMShsm has failed to write the record. The DFSMShsm function running at the time has probably failed as well. See subsequent messages regarding the status of the DFSMShsm function. DFSMShsm processing continues.
Determine whether this is a VSAM error or the result of a previous abnormal end when the control interval was in use. If the record being accessed is critical to DFSMShsm, the control interval can be released by stopping all DFSMShsms that share the control data sets and then restarting them.
DFSMShsm