ARC0652I
ERROR UPDATING DCR RECORD DURING AUTOMATIC EXPIRATION OF DUMP VOLUMES

Explanation

A positioning or read error occurred while DFSMShsm was attempting to update the DCR record for each processing unit during automatic expiration of dump volumes. As a result, the dump volume selection table (DVST) may not be promptly rebuilt in all processing units. This means that the list of available dump volumes may not immediately include the volumes just made available during automatic expiration processing.

The DVST will be rebuilt at DFSMShsm start up during initialization of the dump control task, or when the activity against dump volumes is high enough that a refresh of the contents of the DVST occurs.

See the accompanying message ARC0187I in the DFSMShsm dump activity log for information about the BCDS record which caused the error.

System action

DFSMShsm processing continues.

Programmer response

See the accompanying message ARC0187I in the DFSMShsm dump activity log for information about the BCDS record which caused the error. Correct the error.

Source

DFSMShsm