ANTC8411I
XCOUPLE RELEASE COMPLETE FOR MSESSION(msession_id) MHLQ(mhlq)

Explanation

The XCOUPLE command with RELEASE was successful. The master session msession_id with high-level qualifier of mhlq is no longer in HOLD status and is now free to continue advancing the consistency time for the coupled XRC sessions in the master session. The session status of all coupled sessions changes to NON-INTERLOCKED, and the volume status for all volumes in the sessions changes to AVS (see messages ANTQ8246I and ANTQ8304I for information related to these statuses).

For coupled sessions that are not active and for coupled sessions that are not in COUPLE_FAILED status, the release function is effective immediately on seeing this message.

For coupled sessions that are in COUPLE_FAILED status, the release function will be effective when the XCOUPLE ADD command is issued for each sessions.

System action

XRC functions are active.

System programmer response

This message reports the successful release of the master session from a HOLD status. If an error occurs while processing the XCOUPLE RELEASE request, message ANTC5410E can have been issued to indicate the particular error that occurred. See this message for actions to take to allow the XCOUPLE RELEASE function to complete successfully. If an XCOUPLE RELEASE function should have occurred but has not, search the problem reporting databases for a solution. If no solution exists, contact the IBM® Support Center. Provide the system log and SVC dump of the associated ANTASnnn address space. You can obtain the dump by issuing MODIFY ANTASnnn,DUMP.

Source

Extended remote copy (XRC).