AMD096A
dev volser dsname IS VALID, HOWEVER, IT ALREADY CONTAIN DATA FROM A PREVIOUS DUMP. mm/dd/yyyy hh:mm:ss TITLE:title of the previous dump REPLY 'R' TO REUSE OR 'U' TO USE ANOTHER DATA SET.

Explanation

The predefined output dump data set passed validity checks, however, the first record in the data set does not match the record written by the stand-alone dump utility, AMDSADDD.

In the message text:
dev
The output device number.
volser
The output device volume serial number.
dsname
The output data set name.

System action

If the operator replies 'R', SADMP reuses the output dump data set and continues dumping. If the operator replies 'U', SADMP issues message AMD001A to prompt for an output device.

Operator response

Reply 'R' if the output dump data set should be reused. Note that the existing data in the dump data set will be lost.

Reply 'U' if the output dump data set on the specified output device should not be reused.

Source

Stand-alone dump (SADMP)

Module

AMDSAIDD

Routing code

-

Descriptor code

-