AMD094I
dev volser dsname IS VALID, HOWEVER, IT ALREADY CONTAIN DATA FROM A PREVIOUS DUMP. THE INSTALLATION CHOSE TO ALWAYS REUSE THE DUMP DATA SET.

Explanation

The predefined output dump data set passed validity checks, however, the first record in the data set does not match the record written by the stand-alone dump REXX utility, AMDSADDD. Since REUSEDS=ALWAYS was specified on the AMDSADMP macro, stand-alone dump reuses the output dump data set.

In the message text:
dev
The output device number.
volser
The output device volume serial number.
dsname
The output data set name.

System action

The dump program reuses the data set and continues dumping.

System programmer response

Note that the output data set was reused. The existing data in the dump data set has been lost.

Source

Stand-alone dump (SADMP)

Module

AMDSAIDD

Routing code

-

Descriptor code

-