Explanation
The stand-alone dump program could not read a page
from expanded (extended) storage, even though system control blocks
show that the page was on expanded storage.
In the message text:
- E-FRAME=ffffffff
- ffffffff is the address of the expanded storage
frame that could not be read.
- DATA ERROR
- The page-in operation returned a condition code of 1.
- BLOCK NOT AVAILABLE
- The page-in operation returned a condition code of 3.
- ESTE=eeeeeeee, UNEXPECTED ERROR
- An error occurred in a system control block or in stand-alone
dump processing. eeeeeeee is the address of the
extended storage table entry (ESTE) that stand-alone dump was using
when the error occurred.
See message AMD075I for a summary of expanded
storage errors by address space and by system.
Note: This message
appears only in the stand-alone dump message log written for the VERBEXIT
SADMPMSG subcommand. It does not appear on a console while stand-alone
dump runs.
Source
Module
Routing code
Descriptor code