AMD068I
MVS VIRTUAL STORAGE CANNOT BE DUMPED. {INVALID cb|NO STORAGE FOR SGT}

Explanation

The stand-alone dump (SADMP) program determined that virtual storage could not be dumped because a control block was incorrect or because contiguous storage for a segment table could not be found.

In the message text:
INVALID cb
Indicates which control block is incorrect.
NO STORAGE FOR SGT
The system could not find storage for the segment table.

System action

The SADMP program ends.

Operator response

Ensure that a STORE STATUS function is performed before or as part of the IPL of the SADMP program. Also ensure that the operating system is fully initialized. Both of these are necessary to dump virtual storage.

Try to reIPL the SADMP program, if possible. See z/OS MVS Diagnosis: Tools and Service Aids for information on running the SADMP. If the problem persists, notify the system programmer.

System programmer response

If the problem persists, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

Stand-alone dump (SADMP)

Module

AMDSAPGE

Routing code

-

Descriptor code

-