AMA125I
mod IDR COUNT=nnnn (MAX=mmmm)

Explanation

The IDR record(s) for module (mod), which was just updated, contains nnnn valid entries and mmmm-nnnn empty entries.

System action

None.

System programmer response

If nnnn=mmmm, module (mod) must be reprocessed by the linkage editor before any further updates. For example, if mmmm=19 and nnnn =19, additional IDR space (19 entries) can be created by re-link editing the load module (using INCLUDE).

Source

SPZAP

Module

AMASZIOR

Routing code

2

Descriptor code

-