AMA123I
SYSPRINT I/O ERROR ddd,opr,err, access-method

Explanation

An I/O error occurred while SPZAP was writing in the data set defined by the SYSPRINT DD statement.

In the message text:
ddd
The device address.
opr
The operation in process.
err
The error type.
access-method
The access method in use.

System action

The job step ends.

System programmer response

If the REP operation was successful, rerun the job step after making sure that the associated REP and VERIFY control statements have been removed.

Source

SPZAP

Module

AMASZIOR

Routing code

2,11

Descriptor code

7