AMA115I
SYSIN I/O ERROR ddd,opr,err, access-method

Explanation

An I/O error that could not be corrected occurred when SPZAP attempted to read a control statement from the SYSIN data set.

In the message text:
ddd
The device address.
opr
The operation in process.
err
The error type.
access-method
The access method in use.

System action

Processing ends immediately. Control statements read from the SYSIN data set before the error was encountered will have been processed.

System programmer response

If the error condition is a wrong length record, check the blocksize specified for the SYSIN data set to be sure that it is equal to the actual size of the records in the SYSIN data set. For other error conditions, check the SYSIN DD statement for correct specifications.

Source

SPZAP

Module

AMASZIOR

Routing code

2

Descriptor code

-