AHL911I
I/O ERROR - ABEND CODE abc, RETURN CODE return-code, DATA SET dsname

Explanation

The trace writer has detected an input/output error during OPEN/CLOSE/EOV processing for a data set.

In the message text:
abc
The abend code.
return-code
The return code.
dsname
The name of the data set.

System action

Trace writer processing will continue as long as there are additional trace data sets still available. If all trace data sets are exhausted, then trace writer processing will end.

Operator response

Record the message and notify the system programmer.

System programmer response

Verify that a valid trace data set has been specified for use and restart GTF. If the problem recurs, examine data set in error, or use alternative data set. The data set in error contain valid trace data; however, the results of post processing this trace data are unpredictable.

Source

Generalized trace facility (GTF)

Module

AHLWINIT