AHL144D
A SPECIFIED ASID IS INVALID, RESPECIFY PARAMETERS

Explanation

For the generalized trace facility (GTF), the response to message AHL101A or AHL102A, or the control statements in the GTF parmlib member, specified an incorrect address space identifier for the ASID parameter. The ASID is not valid because of one of the following conditions:
  • The ASID value contains a character that is not a valid hexadecimal character.
  • The value of the ASID is greater than the largest valid ASID value. The system initialization parameter, MAXUSER, defines the largest valid ASID value.
  • The ASID is 0.

System action

GTF ignores all the address space identifiers that the operator specified in response to message AHL101A or AHL102A. The system continues processing, but GTF initialization does not continue until the error is corrected. If the error occurred in the GTF parmlib member, the system issues message AHL124I to identify the error source.

Operator response

If you are entering the control statements through the system console, correct the ASID error and respecify the address space identifiers. If the error is in the GTF parmlib member, notify the system programmer.

System programmer response

If a GTF control statement caused the error, correct the control statement in the GTF parmlib member and restart GTF.

Module

AHLTPMT

Module

Generalized trace facility (GTF)