AHL141D
INVALID VALUE SPECIFIED FOR CCW KEYWORD, RESPECIFY PARAMETERS

Explanation

For the generalized trace facility (GTF), a response to message AHL100A, AHL101A, or AHL102A, or a control statement in the GTF parmlib member, contains an incorrect value. GTF issues this message for misspellings, missing commas, duplicate entries, incorrect parameter values, and the like.

System action

GTF ignores all keywords and values on the response or control statement. The system continues processing, but GTF initialization does not continue until the error is corrected. If the error occurred in the GTF parmlib member, the system issues message AHL124I to identify the error source.

Operator response

In reply to this message, correct the error and enter the line again. If the error is in the GTF parmlib member, notify the system programmer.

System programmer response

If a GTF control statement caused the error, correct the control statement in the GTF parmlib member and restart GTF.

Module

AHLTPMT

Module

Generalized trace facility (GTF)